Các lỗi thường gặp

Code :
  • Code: SC901
  • Description: Mechanical total counter error
    The mechanical counter is not connected.
  • Causes: • Mechanical total counter defective • Mechanical total counter connector not connected
  • Code: SC951
  • Description: F-gate signal error 2
    When the IPU has already received the F-gate signal (laser writing start trigger signal), the IPU receives another F-gate signal.
  • Causes: • SBICU defective
  • Code: SC953
  • Description: Scanner image setting error
    The settings that are required for image processing using the scanner are not sent from the IPU.
  • Causes: • Software defective
  • Code: SC954
  • Description: Printer image setting error
    The settings that are required for image processing using the printer controller are not sent from the IPU.
  • Causes: • Software defective
  • Code: SC955
  • Description: Memory setting error
    The settings that are required for image processing using the memory are not sent from the IPU.
  • Causes: • Software defective
  • Code: SC956
  • Description: Scanner setting ID error
    The ID that is sent from the IPU for scanner parameter setting is different from expected.
  • Causes: • Software error
  • Code: SC957
  • Description: Scanner return ID error
    The ID that is sent from the IPU for the scanner return signal is different from expected.
  • Causes: • Software error
  • Code: SC958
  • Description: Scanner ready ID error
    The ID that is sent from the IPU for the scanner ready signal is different from expected.
  • Causes: • Software error