Description: TD sensor error
TD sensor output voltage falls out of the adjustment target (2.5+- 0.1 V) during the Vt check.
Vt-Vtref>0.6V is detected 10 consecutive times even though toner is detected by the toner end sensor.
Vt<0.5 or Vt>4.0 is detected.
Description: Development bias leak
A development bias leak signal is detected.
Causes: • Sleeve roller receptacle damage • Development bias power pack defective
Code: SC392
Description: Image storage address error
The EX-IPU receives the image data output request signal for data that is not stored in memory
Causes: • Transfer high voltage supply board defective • Transfer belt position sensor defective
Code: SC401
Description: Transfer belt error
A transfer belt current leak signal is detected.
Causes: • Transfer high voltage supply board defective • Transfer belt position sensor defective
Code: SC405
Description: Time out error (scanner)
The BCU does not receive the scanner access ready signal from the EX-IPU
Causes:
Code: SC440
Description: Main motor lock
A main motor lock signal is detected for more than 2 seconds.
Causes: • Too much load on the drive mechanism • Main motor defective
Code: SC490
Description: Ozone fan motor lock/Exhaust fan motor lock
A fan motor lock signal is detected for more than 0.5 second from either fan.
Causes: • Ozone fan motor defective • Exaust fan motor defective • Poor connection of the fan motor connector • Something is stuck in the fan motor
Code: SC501
Description: Main body tray lift motor malfunction
• The paper upper limit sensor is not actuated after the tray lift motor has been on for 10 seconds. • The pick-up roller solenoid does not contact the top sheet of paper