Description: Self-Diagnostic Error: ASIC The ASIC returns an error during the self-diagnostic test at power on because the ASIC and CPU timer interrupts were compared and determined to be out of range.
Causes: • Controller board defective
Code: 824
Description: Self-diagnostic Error: NVRAM The resident non-volatile RAM returns an error during the selfdiagnostic test at power on.
Causes: • NVRAM damaged or abnormal • Backup battery has discharged • NVRAM socket damaged
Code: 827
Description: Self-diagnostic Error: RAM The resident RAM returned a verify error during the self-diagnostic test at power on.
Causes: • Memory malfunction
Code: 828
Description: Self-diagnostic Error: ROM The resident read-only memory returned an error during the selfdiagnostic test at power on.
Description: Electronic total count error • The value of the total count has already exceeded its limit (9,999,999) • During counting, a defect was detected at the mechanical counter.
Causes: • NVRAM defective
Code: 951
Description: F-GATE error at write request After the IPU receives an F-GATE signal, it receives another F-GATE signal (software timeout error)
Causes: • Software defective • BICU defective
Code: 954
Description: Printer setting error The IPU does not respond with the settings required to start printer image processing.
Causes: • Software defective
Code: 955
Description: Memory setting error The IPU does not respond with the settings required to start memory image processing.