Các lỗi thường gặp

Code :
  • Code: 641
  • Description: BICU control data transfer abnormal Data send from BICU to controller failed after 3 attempts.
  • Causes: • Controller board defective • External noise • BICU board defective
  • Code: 690
  • Description: GAVD block I2C bus error An error is detected in the GAVD communication I2C control register of the GABIC2.
  • Causes: • I2C bus on BICU defective
  • Code: 691
  • Description: GAVD FCI block I2C bus error An error is detected in the FCI communication I2C control register of the GABIC2.
  • Causes: • I2C bus on BICU defective
  • Code: 692
  • Description: CDIC GAVD block I2C bus error An error is detected in the CDIC communication I2C control register of the GABIC2.
  • Causes: • I2C bus on BICU defective
  • Code: 722
  • Description: Finisher jogger motor error The finisher jogger H.P. sensor does not return to the home position, or move out of the home position, within the specified time.
  • Causes: • Jogger H.P. sensor defective • Jogger motor defective
  • Code: 724
  • Description: Finisher staple hammer motor error Stapling not complete within 600 ms after the staple hammer motor turns on.
  • Causes: • Staple jam • Stapler overload caused by trying to staple too many sheets • Staple hammer motor defective
  • Code: 725
  • Description: Finisher stack feed-out motor error The stack feed-out belt H.P. sensor does not activate within the specified time after the stack feed-out motor turns on.
  • Causes: • Stack feed-out H.P. sensor defective • Stack feed-out motor overload • Stack feed-out motor defective
  • Code: 726
  • Description: Finisher shift tray 1 lift motor error • Tray shift does not finish within the specified time after the shift motor turns on • Stack height sensor does not activate within the specified time after the shift tray lift motor turns on.
  • Causes: • Shift motor defective or overloaded • Shift tray lift motor defective or overloaded