Description: Fusing overheat error A fusing temperature of over 245 °C is detected for 1 second by the fusing thermistor. A fusing temperature of over 235 °C is detected for 1 second after the fusing lamp has been turned off. The dual monitoring circuitry of the BICU detects extremely high temperature and tripped the relay circuit off.
Causes: • Fusing thermistor defective • Power supply board defective
Description: Unstable fusing temperature During standby, within 500 ms, the fusing temperature goes below 60 °C twice or over 60 °C three times. Within 1 minute, a 60 °C increase or decrease in fusing temperature is detected during five different one-second intervals.
Causes: • Fusing thermistor defective • Power supply board defective • Defective connection of the fusing unit
Description: G112/ G113 Only Fusing fan motor error The CPU detects an exhaust fan lock signal for more than 3.5 seconds. The engine board cannot communicate with the duplex unit.
Causes: • Poor connection of the exhaust fan motor • Too much load on the motor drive
Description: Engine to controller communication error.
Causes: • Examine the connection between the controller and the engine board. • Replace the engine board if the error is frequent. • Replace the controller if the error is frequent.