Description: Polygon motor error: Time out with the polygon motor activated [D] After the polygon motor turns on or changes the speed, the SCRDY_N is not active within 10 seconds.
Causes: • Disconnected cable from the polygon motor drive board or defective connection • Defective polygon motor or drive board
Description: Polygon motor error: Time out with the polygon motor inactivated [D] After the polygon motor turns off or changes the speed, the SCRDY_N is not inactive within 10 seconds.
Causes: • Disconnected cable from the polygon motor drive board or defective connection • Defective polygon motor or drive board
Description: Polygon motor error: XSCRDY signal error [D] PMRDY_N signal consecutively detects that the polygon motor is an inactive state while LDB unit scans.
Causes: • Disconnected cable from the polygon motor drive board or defective connection • Defective polygon motor or drive board
Remedy: 1. Check the connectors. 2. Replace the polygon motor. 3. Replace the polygon motor drive board.
Description: Polygon motor error: XSCRDY signal not stable [D] PMRDY_N signal consecutively detects that the polygon motor is an inactive state while the polygon motor turns on or changes the speed.
Causes: • Disconnected cable from the polygon motor drive board or defective connection • Defective polygon motor or drive board.
Remedy: 1. Check the connectors. 2. Replace the polygon motor. 3. Replace the polygon motor drive board.
Description: Trailing edge laser detection error: [K] [C] The laser synchronizing detection signal for LDB [K] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Description: Trailing edge laser detection error: [Y] [C] The laser synchronizing detection signal for LDB [Y] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Description: Trailing edge laser detection error: [M] [C] The laser synchronizing detection signal for LDB [M] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.