Các lỗi thường gặp

Code :
  • Code: 243
  • Description: LDB error [C] [D] The EGB detects LDB error a few times consecutively when LDB unit turns on after LDB initialisation.
  • Causes: • Defective LDB
  • Remedy: 1. Replace the LDB.
  • Code: 270
  • Description: LDU shutter error [D] Sensor output does not change even if 1 second passes after the LDU shutter motor is on.
  • Causes: • Sensor defective or LDU shutter motor defective
  • Remedy: 1. Replace the LDU shutter sensor or shutter motor.
  • Code: 300
  • Description: High voltage power board: Charge voltage output error [K] [D] The measured voltage is not proper when EGB measures the charge output for each color.
  • Causes: • Defective charge roller • Defective connectors • Disconnected harness • Defective high voltage power 1
  • Remedy: 1. Check the connectors. 2. Replace the PCU for black. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
  • Code: 301
  • Description: High voltage power board: Charge voltage output error [M] [D] The measured voltage is not proper when EGB measures the charge output for each color.
  • Causes: • Defective charge roller • Defective connectors • Disconnected harness • Defective high voltage power 1
  • Remedy: 1. Check the connectors. 2. Replace the PCU for magenta. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
  • Code: 302
  • Description: High voltage power board: Charge voltage output error [C] [D] The measured voltage is not proper when EGB measures the charge output for each color.
  • Causes: • Defective charge roller • Defective connectors • Disconnected harness • Defective high voltage power 1
  • Remedy: 1. Check the connectors. 2. Replace the PCU for cyan. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
  • Code: 303
  • Description: High voltage power board: Charge voltage output error [Y] [D] The measured voltage is not proper when EGB measures the charge output for each color.
  • Causes: • Defective charge roller • Defective connectors • Disconnected harness • Defective high voltage power 1
  • Remedy: 1. Check the connectors. 2. Replace the PCU for yellow. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
  • Code: 304
  • Description: Charge AC bias error [K] [D] The charge current less than 200 µA is detected.
  • Causes: • Defective charge roller • Defective connectors • Disconnected harness • Defective high voltage power 1
  • Remedy: 1. Check the connectors. 2. Replace the PCU for black. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.
  • Code: 305
  • Description: Charge AC bias error [M] [D] The charge current less than 200 µA is detected.
  • Causes: • Defective charge roller • Defective connectors • Disconnected harness • Defective high voltage power 1
  • Remedy: 1. Check the connectors. 2. Replace the PCU for magenta. 3. Replace the drum positioning plate. 4. Replace the high voltage power 1.