Description: [0B00] Self-diagnostic error - ASIC ASIC and CPU timer error detected during selfdiagnostic.
Causes: • Defective controller
Remedy: 1. Replace the controller if the error is frequent.
Code: 821
Description: [0D05] Self-diagnostic error. ASIC The CPU checks if the ASIC timer works properly compared with the CPU timer. If the ASIC timer does not function in the specified range, this SC code is displayed.
Causes: • System firmware problem • Defective RAM-DIMM • Defective controller
Remedy: 1. Reinstall the controller system firmware. 2. Replace the RAM-DIMM. 3. Replace the controller board.
Code: 822
Description: [3003] Self-diagnostic error. HDD: Time out error When the main switch is turned on or starting the self-diagnostic, the HDD stays busy for the specified time or more.
Remedy: 1. Check that the HDD is properly connected to the controller. 2. Replace the HDD. 3. Replace the controller.
Code: 822
Description: [3004] Self-diagnostic error. HDD: Command error When the main switch is turned on or starting the self-diagnostic, the diagnostic error from HDD occurs.
Causes: • Defective HDD
Remedy: 1. Replace the HDD.
Code: 823
Description: [6101] Self-diagnostic error . NIC: MAC address check sum error The result of the MAC address check sum does not match the check sum stored in ROM.
Causes: • Defective controller
Remedy: 1. Replace the controller.
Code: 823
Description: [6104] Self-diagnostic error . NIC: PHY IC error The PHY IC on the controller cannot be properly recognized.
Causes: • Defective controller
Remedy: 1. Replace the controller.
Code: 823
Description: [6105] Self-diagnostic error . NIC: PHY IC loop back error An error occurred during the loop-back test for the PHY IC on the controller.
Causes: • Defective controller
Remedy: 1. Replace the controller.
Code: 824
Description: [1401] Self-diagnostic error . NVRAM [D] The controller cannot recognize the standard NVRAM installed or detects that the NVRAM is defective.