Description: Fusing (hot roller) low temperature Type: 1 - Description - The main control board notifies the SCU when the fusing (hot roller) thermistor outputs an analog value corresponding to 90°C after it had previously reached the ready temperature. - Detection Timing - Always
Causes: • Fusing (hot roller) thermistor • Main control board SP-Log: 7-402-5
Code: SC545
Description: Fusing (hot roller) ready temperature abnormal Type: 1 - Description - The main control board notifies the SCU when the fusing (hot roller) thermistor outputs an analog value corresponding to a temperature lower than the ready temperature for 6 minutes or more after it had previously reached the ready temperature. - Detection Timing - Always
Causes: • Fusing (hot roller) thermistor • Main control board SP-Log: 7-402-5
Code: SC547
Description: Fusing (hot roller) temperature does not increase Type: 1 - Description - The main control board notifies the SCU when the output of the fusing (hot roller) thermistor increases by no more than 3°C for a minute during warming up after the power switch is turned on. - Detection Timing - When the power switch is turned on
Causes: • Fusing (hot roller) thermistor • Main control board SP-Log: 7-402-5
Code: SC551
Description: Pressure roller thermistor open Type: 1 - Description - When the pressure roller thermistor outputs an analog value corresponding to 0°C, the main control board determines that the pressure roller thermistor is broken and notifies the SCU of it. - Detection Timing - Always
Causes: • Pressure roller thermistor • Main control board SP-Log: 7-402-5
Code: SC552
Description: Pressure roller warm-up error Type: 1 - Description - The main control board notifies the SCU when the pressure roller thermistor does not output an analog value corresponding to the ready temperature within 12 minutes after the power switch is turned on. - Detection Timing - When the power switch is turned on
Causes: • Pressure roller thermistor • Main control board SP-Log: 7-402-5
Code: SC553
Description: Pressure roller overheat Type: 1 - Description - When the pressure roller thermistor outputs an analog value corresponding to 200°C, the main control board judges an overheat and notifies the SCU of this. - Detection Timing - Always
Causes: • Pressure roller thermistor • Main control board SP-Log: 7-402-5
Code: SC554
Description: Pressure roller low temperature Type: 1 - Description - The main control board notifies the SCU when the pressure roller thermistor outputs an analog value corresponding to 70°C after it had already reached the ready temperature. - Detection Timing - At all times
Causes: • Pressure roller thermistor • Main control board SP-Log: 7-402-5
Code: SC555
Description: Pressure roller ready temperature abnormal Type: 1 - Description - The main control board notifies the SCU when the pressure roller thermistor outputs an analog value corresponding to a temperature lower than the ready temperature for 6 minutes or more after it had already reached the ready temperature. - Detection Timing - At all times
Causes: • Pressure roller thermistor • Main control board SP-Log: 7-402-5