Các lỗi thường gặp

Code :
  • Code: 549
  • Description: Fusing-temperature range violation (too low)
    During paper transport, fusing temperature fell below lower limit (155°C) and remained below limit for 6 seconds.
  • Causes: • Fusing thermistor defective • PSU defective
  • Code: 550
  • Description: Standby temperature error 1
    Fusing temperature failed to drop to expected level within a given time (15 seconds, 15 minutes, or 25 minutes, depending on mode) after entering standby or low-power mode.
  • Causes: • TRIAC short • Fan not running
  • Code: 551
  • Description: Standby overheat
    Temperature during standby or low-power mode remained too high for a specified interval (10 seconds or 25 seconds, depending on the mode).
  • Causes: • TRIAC short
  • Code: 552
  • Description: Standby low temperature error
    After reaching expected temperature in low-power mode (level 1) or standby mode, temperature fell and remained below 155°C for 20 seconds.
  • Causes: • Fusing thermistor defective • PSU defective
  • Code: 692
  • Description: Communication error between FCU and printer controller
    Printer failed to acknowledge message from FCU within 1.2 seconds.
  • Causes: • Printer controller defective • FCU defective • Poor connection between FCU and printer controller
  • Code: 900
  • Description: Electrical total counter error
    The electrical total counter is not working properly.
  • Causes: • SRAM defective. The only way to correct this error is to replace the FCU.
  • Code: 901
  • Description: Mechanical total counter
    The mechanical total counter is not working properly.
  • Causes: • Mechanical total counter disconnected