Các lỗi thường gặp

Code :
  • Code: 302
  • Description: Charge roller current leak
    Current leak at the charge roller was detected.
  • Causes: • Charge roller damaged • High voltage supply board defective • Poor connection of the PCU
  • Code: 320
  • Description: Polygon mirror motor error
    Did not detect lock signal from polygon mirror motor within 10 seconds after motor ON signal; or, lost lock signal for continuous 1.5 seconds after signal was detected.
  • Causes: • Polygon mirror motor (or harness) defective • FCU defective
  • Code: 322
  • Description: Laser synchronization error
    Detected LD error signal for continuous 1.5 seconds while polygon mirror motor was running at constant speed.
  • Causes: • Synchronization detection mirror defective • LD unit defective • FCU defective • LD harness damaged • THM not in place
  • Code: 390
  • Description: TD sensor error
    The TD sensor output less than 0.33 V or greater than 2.64 V ten times in succession.
  • Causes: • TD sensor defective • Bad connection
  • Code: 391
  • Description: Development bias leak
    Development bias leak signal was detected.
  • Causes: • Development roller defective • High voltage supply board defective
  • Code: 392
  • Description: Developer initialization error
    Error reading ID sensor pattern during developer initialization.
  • Causes: • Forgot to remove heat seal from replacement PCU • ID sensor defective • TD sensor defective • Drum is not turning • Development roller is not turning • Right door not closed firmly
  • Code: 401
  • Description: Transfer roller leak error 1 ("+" leak)
    A current leak signal for the transfer roller was detected. (Current feedback signal was not detected for at least 200ms).
  • Causes: • Transfer roller damaged • High voltage supply board defective • Poor connection between transfer unit and machine • Transfer unit set incorrectly
  • Code: 402
  • Description: Transfer roller leak error 2 ("-" leak)
    A current leak signal for the transfer roller was detected. (Current feedback signal was not detected for at least 200ms).
  • Causes: • Transfer roller damaged • High voltage supply board defective • Poor connection between transfer unit and machine • Transfer unit set incorrectly