Các lỗi thường gặp

Code :
  • Code: SC240
  • Description: LD Error
    The LD error terminal of the LDB asserted an error.
  • Causes: • Cycle the machine off/on
    • LDB harness connectors loose, broken, defective
    • LDB defective
    • IPU defective
    • BCU defective
  • Code: SC300
  • Description: Charge Corona Error 1: Charge Leak
    A abnormal detection signal (H) was detected for more than 60 ms. Also, during this time, the detected voltage remained below –4V for more than 50 ms.)
  • Causes: • Cycle the machine off/on
    • CGB power pack harness connectors loose, broken, defective
    • Corona wire caps loose, missing
    • CGB power pack defective
    • Charge corona unit connectors loose, broken, defective
  • Code: SC304
  • Description: Charge Corona Error 2: Grid Leak
    A high feedback voltage (H) for the charge corona 60 ms. Also, during this time, the voltage of the charge grid remained less than –400V
  • Causes: • Cycle the machine off/on
    • Charge unit set incorrectly (not locked in place)
    • Charge unit connector loose, broken, defective
  • Code: SC305
  • Description: Charge Corona Wire Cleaner Error 1
    One of these occurred after the charge corona cleaner motor was switched on: • The charge corona wire cleaner motor remained locked within 10 sec after the motor switched on. • The charge corona wire cleaner motor failed to lock within 45 s after the start of cleaning.
  • Causes: • Cycle the machine off/on
    • Charge corona wire cleaner motor defective
  • Code: SC306
  • Description: Charge Corona Wire Cleaner Error 2
    The cleaning pad of the charge corona wire cleaner mechanism failed to return to its home position.
  • Causes: Connectors between motor and IOB loose, broken, defective
    • Charge wire dirty, defective, broken
    • Wire cleaning pad defective
    • Motor or motor board in motor unit defective
  • Code: SC312
  • Description: Pre-Charge Output Error 1: Leak
    An abnormal signal (H) was detected continuously for 60 ms. During this time the pre-charge unit voltage remained less than –3 kV for more than 50 ms.
  • Causes: • Pre-charge unit set incorrectly.
    • Pre-charge unit contact is broken or defective.
  • Code: SC313
  • Description: Pre-Charge Output Error 1: Grid Output
    An abnormal signal (H) was detected continuously for 60 ms. During this time the pre-charge grid voltage remained less than –400V for more than 50 ms.
  • Causes: • Pre-charge unit set incorrectly
    • Pre-charge unit contact is broken or defective
  • Code: SC320
  • Description: Development Bias Error
    An abnormal detection signal (H) was detected continuously for 60 ms. During this time the voltage exceeded –90µA for more than 50 ms
  • Causes: • Development power pack connectors loose, broken, defective
    • Development unit connectors loose, broken, defective
    • Development power pack defective