Code :
  • Code: SC128
  • Description: Scanner Motor Error 4
    The scanner motor speed does not reach the target speed by the time the scanning start point is reached.
  • Causes: • Scanner motor defective
    • Overload on scanner mechanism • PSU-Eb board defective
    • MCU board defective (scanner motor control unit)
  • Code: SC129
  • Description: Scanner Motor Error 5
    The scanner motor speed is abnormal. The machine will not stop scanning even after the machine detects that motor speed is abnormal.
  • Causes: • Scanner motor defective
    • Scanner drive mechanism defective
    • PSU-Eb board defective
    • MCU board defective (scanner motor control unit)
  • Code: SC141
  • Description: Black level detection error
    When the scanner was turned on, AGC (automatic gain control) failed to achieve the target value of 10 ±3.
  • Causes: • SBUÅÆ IPU harnesses defective
    • BCU ÅÆ IPU harnesses defective
    • SBU defective
    • IPU defective
    • BCU defective
  • Code: SC142
  • Description: White level detection error
    When the scanner was turned on, the second sampling by AGC (automatic gain control) failed to achieve a value within the range –7 to 0 of the target value 128.
  • Causes: • Standard white plate defective, dirty
    • Moisture inside the scanner unit
    • SBUÅÆ IPU harnesses defective
    • BCU ÅÆ IPU harnesses defective
    • SBU defective
    • IPU defective
    • BCU defective
  • Code: SC143
  • Description: SBU Error 1
    When the scanner was turned on, the SBU (Sensor Board Unit) level adjustment, black level check, and final SBU white level check failed.
  • Causes: • SBU defective
    • IPU defective
    • BCU defective
    • Harness between the SBU and IPU defective
    • Harness between the BCU-IPU defective
    • Standard white plate not installed correctly, or is dirty
    • Scanner mirrors and/or lenses are dirty or installed incorrectly
  • Code: SC144
  • Description: SBU Error 2
    At power on:
    • The SYDI terminal signal did not go HIGH within 1 s
    • The specified SBU (Sensor Board Unit) ID (GASBUP and LM98513) could not be read after 3 tries
  • Causes: • SBU defective
    • BCU defective
    • Harness between SBU and IPU defective
  • Code: SC161
  • Description: IPU Error
    At power on, or when the machine returns from an energy save mode, the self-diagnostic program returned an IPU error.
  • Causes: • IPU defective
    • Connection between SBU and IPU is loose, broken, or defective
  • Code: SC165
  • Description: Illegal Copy Data Security Error
    The "Data Security for Copying Feature" in the User Tools is set to "ON" without the ICIB-2 installed.
  • Causes: • Copy Data Security Unit option board is not installed
    • Copy Data Security Unit board is defective
    Note:
    • The "Data Security for Copying" feature in the User Tools must be set to "OFF" before the ICIB-2 is removed.
    • To switch this feature off/on: [User Tools]> System Settings> Administrator Tools> Next.> Data Security for Copying> Select Off/On.