Description: Communication Error Between BCU and ADF 1
There was no response from the ADF 100 ms after the ACK signal was sent to the ADF. Three attempts to resend the data failed.
Causes: • Poor connection between the BCU board and the ADF main board
• Interference from external noise on the harness between the BCU and ADF
Code: SC621
Description: Communication Error Between BCU and ADF 2
The machine detected a break signal (LOW) from the line connection between the BCU and ADF
Causes: • Serial line connection unstable
• Harness, connectors between ADF and BCU loose, broken, defective
Code: SC622
Description: Communication Error Between BCU and ADF 3
Software error after improper user operation.
Causes: • Software error
• Cycle the machine off/on
Code: SC625
Description: Communication Error Between BCU and Finisher
The BCU cannot communicate with the finisher properly. here was no response from the ADF 100 ms after the ACK signal was sent to the ADF. Three attempts to resend the data failed.
Causes: • Poor connection between the BCU board and the finisher main board
Code: SC626
Description: Communication Error Between BCU and Finisher
A break signal (LOW) was detected.
Causes: • Poor connection between the BCU board and the finisher main board
• Finisher main board defective
• BCU board defective
• External electrical noise on the interface cable caused the serial line to become unstable
Code: SC630
Description: CSS Communication
Japan Only
Causes:
Code: SC632
Description: Charge Unit Device Error 1
Japan Only
Causes:
Code: SC633
Description: Charge Unit Device Error 2
Japan Only