Description: Scanner board communication error
• BICU does not get a signal from the scanner board for 1.5 seconds or more.
• BICU gets a break-signal after completing the communication with the scanner board and does not get a signal from the scanner board for 10 seconds or more.
Causes: • Defective communication between BICU and scanner board
Description: Memory error
An error occurs during the memory check conducted when the main power switch is turned on or when the copier is recovering from the energy saver mode.
Causes: • Defective memory
• Defective BICU
• Loose connection between the BICU and the memory