Description: Polygonal mirror motor error
The polygon mirror motor does not reach the operating speed within 10 seconds. Or, the polygon mirror motor remains out of the operating speed for 0.2 second after reaching the operating speed.
Causes: • Defective polygon mirror motor
• Loose connection between the polygonal mirror motor and the BICU
• Defective cable between the BICU and the polygon mirror motor
• Defective BICU
Description: No laser writing signal (F-GATE) error
The poling module does not detect the laser writing signal (F-GATE) asserting after the laser crosses 5 mm from the start point on the drum surface.
Causes: • Defective BICU
• Loose connection on the fax controller or the printer controller
• Defective fax controller or printer controller
Description: Laser synchronization error
The main scan synchronization detector does not detect the laser signal for 0.5 second.
Causes: • Toner bottle not installed
• Loose connection between the LD unit and the BICU
• Defective cable between the BICU and LD unit
• LD unit out of position
• Defective LD unit
• Defective BICU
Description: TD sensor error
The BICU detects the TD sensor outputting extraordinary voltage (less than 0.2 V or more than 4.0 V) 10 times consecutively.
Causes: • Defective TD sensor
• Loose connection of the PCU
Description: Developer initialization error
The ID sensor does not detect a correct pattern during developer initialization (* 2-214-001).
Causes: • Defective ID sensor
• Insufficient developer
• Defective drum operation
• Defective development roller operation
• Loose connection of the PCU
• Insufficient voltage for the charge roller
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.