Code: 546

Description: Unstable fusing temperature (center)
The fusing temperature varies 50° C or more within 1 second, and this occurs 2 consecutive times.
Causes: • Thermistor defective or out of position
• Power supply unit defective

Code: 547

Description: Zero cross signal malfunction
Zero cross signals are not detected within 5 seconds after the main power switch is turned on, or are not detected within 1 second after operation begins.
Causes: • Power supply board defective
• BICU defective

Code: 559

Description: Jam error detected 3 times in succession
The exit sensor and the duplex sensor detect a paper jam 3 times in succession This condition can occur when SP 1159 1 is set to ‘on’. The default is ‘off’.
Causes: Paper jams can occur for the following reasons.
• Dampness
• Paper curl
• Incorrect paper setting in the paper tray
• Stripper pawls coming apart

Code: 590

Description: Left exhaust fan motor error
The CPU detects an exhaust fan lock signal for more than 5 seconds.
Causes: • Loose connection of the exhaust fan motor
• Too much load on the motor drive

Code: 591

Description: Rear exhaust fan motor error
The CPU detects an exhaust fan lock signal for more than 5 seconds.
Causes: • Loose connection of the exhaust fan motor
• Too much load on the motor drive

Code: 620

Description: Communication error between BICU and ADF
The BICU does not receive a response from the ADF main board for 4 seconds or more. The BICU receives a break signal from the ADF main board.
Causes: • Poor connection between the BICU and
ADF main board (DF connector)
• ADF main board defective
• BICU defective

Code: 621

Description: ADF connection error
An incorrect ADF (an ADF for some other copier) is detected.
Causes: • ADF incorrect (The ADF for B039/B040/ B043 or B121/B122/B123/B259/ B260/B261 is installed on a B282/B283)
• The connector of the ADF is removed while the machine is in the energy saver mode

Code: 692

Description: Controller board communication abnormal
Communication error between the printer part of the controller board and BICU.
Causes: • The connector is abnormal between the controller board and the BICU board.