Description: Unstable fusing temperature
While the fusing lamp is on, the fusing temperature varies 50°C or more within one second; and this occurs two consecutive times.
Causes: • Defective thermistor
• Incorrect installation of the thermistor
• Defective power supply unit
Code: 547
Description: Zero cross signal malfunction
The zero cross signal is not detected within five seconds after the main power switch is turned on. Or, the zero cross signal is not detected within one second after operation begins.
Causes: • Defective power supply unit
• Defective BICU
Code: 559
Description: Consecutive fusing jam
The paper jam counter for the fusing unit reaches 3 times. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when SP1159-001 is set to "1" (default "0").
Causes: • Paper jam in the fusing unit.
Code: 590
Description: Exhaust fan motor error
The exhaust fan motor is locked for five seconds.
Causes: • Loose connection of the exhaust fan motor
• Overload
Code: 632
Description: MF accounting device error 1
The machine sends a data frame. No normal end signal returns. This symptom happens three times.
Causes: • Defective or broken line between machine and device
Code: 633
Description: MF accounting device error 2
The machine is communicating with the accounting device. The break signal returns.
Causes: • Defective or broken line between machine and device
Code: 634
Description: MF accounting device error 3
A backup RAM error is reported from the accounting device.
Causes: • Defective accounting device controller • Defective battery in the accounting device
Code: 635
Description: MF accounting device error 4
A battery voltage error is reported from the accounting device.
Causes: • Defective accounting device controller
• Defective battery in the accounting device