Mã lỗi Ricoh Aficio MP2510 — Trang 2/17
Code:
Tất cả lỗi (136)
101
102
120
121
122
123
141
143
144
165
193
195
196
197
198
199
302
320
322
323
350
351
352
353
354
355
389
390
391
392
398
399
401
402
411
490
500
501
502
503
504
506
508
509
510
520
541
542
543
544
545
546
547
548
557
590
611
612
620
621
650
669
670
672
720
721
722
724
725
726
727
728
730
731
732
770
791
792
793
800
804
818
819
820
821
822
823
824
826
827
828
829
838
840
841
850
851
853
854
855
856
857
860
861
862
863
864
865
866
867
868
870
872
873
874
875
876
880
900
901
920
921
925
951
953
954
955
964
984
986
990
991
992
995
997
998
Description: SBU connection error
The IPU does not detect the SBU connection signal.
Causes: Harness between SBU and IPU board loose, disconnected, or damaged.
Description: Copy Data Security Unit error
An error occurred when the machine attempted to recognize the Copy Data Security Unit board.
Causes: • The Copy Data Security Unit board is not installed • The Copy Data Security Unit board is installed, but it is not the correct type for the machine.
Description: Image transfer error
The IPU board does not finish within 1 minute after the image data has been transferred to the controller board.
Causes: • IPU board defective • Controller board defective • Video controller defective
Description: DFGATE assert error
The DFGATE signal does not assert within 30 seconds after the original has been scanned.
Causes: • ADF interface cable loose, disconnected, or damaged • SBCU defective • Mismatched firmware between the SBCU board and ADF
Description: DFGATE negate error
The DFGATE signal does not negate within 1 minute after the DFGATE has been asserted.
Causes: • ADF interface cable defective • SBCU defective • Mismatched firmware between the SBCU board and ADF
Description: DFGATE error
The DFGEATE signal has already been asserted at the original scan.
Causes: • ADF interface cable defective • SBCU board defective • Mismatched firmware between the SBCU board and ADF
Description: Memory address error
The IPU board does not receive the memory address from the controller board.
Causes: • Mismatched firmware between the SBCU board and controller board • Controller defective • SBCU defective • IPU board defective Note: Before you replace a board, update the firmware. This can repair the error.
Description: DF scanning finish error
The original does not finish scanning with in 1 minute
Causes: • ADF interface cable defective • SBCU board defective • Mismatched firmware between the SBCU board and ADF