Description: Charge level output error The PWM output level was detected higher than 50% after 10 consecutive samplings.
Causes: • high voltage power supply board defective • Harness of the high voltage power supply board (power pack) is loose, broken. • PCU connection loose or broken
Remedy: • Cycle the main power off/on • Replace the high voltage power supply board • Replace the harness of the power pack. • Replace the harness of the PCU. • Replace the PCU.
Description: ID sensor error • One of the following conditions occurred when the ID sensor pattern was calibrated during printing: Vsp > 2.5V, Vsg < 2.5V, Vsp = 0V, Vsg = 0V • The following conditions occurred simultaneously when the ID sensor pattern was calibrated during printing: Vsg = 5V, PWM = 0 (LED current drop) • Error occurred during automatic adjustment of Vsg: Vsg output did not attain 4V, even with PWM = 1023 (maximum current for LED) Vsg output was greater than 4V, even with PWM=1 (no current for the LED)
Causes: • ID sensor dirty or defective • ID sensor harness disconnected, or connector damaged • BCU defective • High voltage power supply board (power pack) defective • Scanning system or image creation system malfunction
Remedy: • Replace the ID sensor harness. • Replace the ID sensor. • Replace the harness of the high voltage power supply board (power pack). • Replace the harness of the BCU. • Replace the BCU.
Description: TD sensor error 1 TD sensor output was less than 0.5V, or more than 0.5V 10 times in succession. If the fax unit is installed, this SC is issued immediately. If the fax unit is not installed, this SC is issued after the prescribed number of copies has printed.
Causes: • TD sensor abnormal • Poor connection of the TD sensor harness
Remedy: • Replace the TD sensor. • Replace the harness of the TD sensor.
Description: TD sensor error 2 The TD sensor outputs less than 0.5V or more than 4.0V 10 times consecutively during copying. Note: If the fax option is installed, this SC is issued immediately. If the fax option is not installed, this SC is issued after the prescribed number of pages is copied.
Causes: • TD sensor abnormal • Poor connection of the TD sensor harness
Remedy: • Replace the TD sensor. • Replace the harness of the TD sensor.
Description: Development bias leak The PWM output level was detected higher than 50% after 10 consecutive samplings.
Causes: • high voltage power supply board defective • High voltage power supply board (power pack) harness loose, broken. • PCU connection loose or broken
Remedy: • Cycle the main power off/on • Replace the harness of the high voltage power supply board (power pack). • Replace the PCU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.