Description: IPU Error (LSYNC abnormal) An error occurred during the self-diagnostic test performed every time the machine is turned on, or returns to full operation from energy save mode.
Remedy: • Replace the IPU (or BCU) board. • Check the cable between SBU and IPU (or BCU)
Code: SC165
Description: Copy data security unit error
Causes: • The copy data security option is enabled in the User Tools but the option board is detected as missing or defective. • The copy data security option was detected as defective when the machine was turned on or returned from energy save mode. • Copy data security unit board not installed correctly • Copy data security unit board defective
Remedy: • Reinstall the copy data security unit board. • Replace the copy data security unit board.
Code: SC195
Description: Machine serial number error Comparison of the product identification code in the machine serial number (11 digits).
Causes: The product identification code in the machine serial number (11 digits) does not match.
Remedy: Re-enter the machine serial number.
Code: SC202
Description: Polygon Motor: ON Timeout Error After the polygon motor turned on, or within T1 sec. after the rpm’s changed, the motor did not enter READY status.
Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective • Polygon motor drive pulse cannot be output correctly. (Polygon controller) • XSCRDY signal observation failing (Polygon controller)
Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
Code: SC203
Description: Polygon Motor: OFF Timeout Error The XSCRDY signal (polygon ready) never becomes inactive (H) within 3 sec. after the polygon motor went OFF.
Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective • Polygon motor drive pulse cannot be output correctly. (Polygon controller) • XSCRDY signal observation failing (Polygon controller)
Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
Code: SC204
Description: Polygon Motor: XSCRDY Signal Error During polygon motor rotation, the XSCRDY signal was inactive (H) for longer than one rotation of the polygon.
Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective
Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
Code: SC220
Description: Laser synchronization detection error: LD0 The laser synchronizing detection signal for the start position of the LD was not output for 500 msec. after LDB unit turned on with the polygon motor rotating normally.
Causes: • The interface harness to the synchronization detection unit damaged or not connected correctly. • Synchronization detection board defective • Beam does not enter photo detector. • Abnormality around GAVD • IDB (LED driver) defective • LDB defective • IPU defective
Remedy: • Turn the power off/on • Replace the laser unit or polygon motor • Replace the polygon harness • Replace the IPU board
Code: SC230
Description: FGATE ON error The FGATE signal did not turn ON within 1 sec. after the writing process started.
Causes: • GAVD defective • Image processing ASIC defective • IPU, controller board not connected correctly or defective • Harness between IPU and LDB defective
Remedy: • Turn the power off/on • Replace the IPU board • Replace the controller board