Code: SC992-00

Description: Undefined SC issued. An SC, that is not controlled by the system, occurred.
Causes: • An SC for the previous model was used mistakenly, etc. • Basically a software bug.
Remedy: Turn the main power off/on.

Code: SC995-01

Description: CPM setting error 1 Comparison of machine serial number (11 digits) and machine identification code. Details: • Machine serial number cannot be identified because of BICU replacement or malfunctioning. • Machine serial number cannot be identified because of NV-RAM replacement
Causes: Machine serial number (11 digits) or machine identification code does not match.
Remedy: Enter the machine serial number using SP5-811, and then turn the power on/off. Attach the NV-RAM that was installed previously.

Code: SC995-02

Description: CPM setting error 2 Comparison of machine serial number (11 digits) and machine identification code. Details: Machine serial number cannot be identified because of NV-RAM replacement or malfunctioning.
Causes: Machine serial number (11 digits) or machine identification code does not match.
Remedy: • Attach the NV-RAM that was installed previously. • Download data on the NV-RAM using SP5-825.

Code: SC995-03

Description: CPM setting error 3 Comparison of machine serial number (11 digits) and machine identification code. Details: Unable to recognize machine identification code because the controller was replaced incorrectly or is malfunctioning.
Causes: Machine serial number (11 digits) or machine identification code does not match.
Remedy: Replace it with a specified controller.

Code: SC995-04

Description: CPM setting error 4 Comparison of machine serial number (11 digits) and machine identification code.
Causes: Machine serial number (11 digits) or machine identification code does not match.
Remedy: Return the parts to the original configuration, and then replace them according to the manual.

Code: SC997-00

Description: Application function selection error The application selected by the operation panel key operated abnormally (No response, abnormal ending).
Causes: Software bug (mainly the application)
Remedy: • Check the optional RAM, DIMM, boards required by the application program. • Check if the combination of downloaded programs are correct.

Code: SC998-00

Description: Application start error • No application was registered to system within a specified time after the main power was turned on. (No application starts/All applications have been terminated abnormally) • Application started but cannot be drawn now for some reason.
Causes: • Software bug (mainly the application) • The optional RAM, DIMM, boards required by the application program. Are not installed correctly.
Remedy: • Turn the main power off/on. • Check the optional RAM, DIMM, boards • Check the combination of programs • Replace the controller board.