Causes: Received a error notification during EEPROM communication and doesnot resume after 3 retries. • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU
Code: SC669-12
Description: EEPROM Data write: Channel error
Causes: Received a error notification during EEPROM communication and doesnot resume after 3 retries. • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU
Code: SC669-13
Description: EEPROM Data write: Device error
Causes: Received a error notification during EEPROM communication and doesnot resume after 3 retries. • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU
Code: SC669-14
Description: EEPROM Data write: Communication abort error
Causes: Received a error notification during EEPROM communication and doesnot resume after 3 retries. • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU
Code: SC669-15
Description: EEPROM Data write: Communication timeout error
Causes: Received a error notification during EEPROM communication and doesnot resume after 3 retries. • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU
Code: SC669-16
Description: EEPROM Data write: Operation stopped error
Causes: Received a error notification during EEPROM communication and doesnot resume after 3 retries. • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU
Code: SC669-17
Description: EEPROM Data write: Buffer full
Causes: Received a error notification during EEPROM communication and doesnot resume after 3 retries. • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU
Code: SC669-18
Description: EEPROM Data write: No error code
Causes: Received a error notification during EEPROM communication and doesnot resume after 3 retries. • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU