Description: Central NC Sensor Short-circuit AD value: 0-13 (FB voltage: 0.000V-0.041V) is detected for specified seconds continuously. Detection period: 100 ms, detection frequency: 10 times or more.
Description: Fusing Central Thermopile Does Not Reload When the fusing central thermopile does not reach a predetermined temperature for 7 seconds consecutively.
Causes: • Thermopile lens dirt • Thermopile modification/float • Outside input voltage guarantee • After excessive temperature rise prevention unit operation
Remedy: • Replace the thermopile. • Check that the input voltage is within acceptable limits.
Description: Fusing Central Thermopile Does Not Reload When the fusing central thermopile does not reach the permission temperature of heat central reloading for specified seconds continuously.
Causes: • Thermopile lens dirt • Thermopile modification/float • Outside input voltage guarantee • After excessive temperature rise prevention unit operation
Remedy: • Replace the thermopile. • Check that the input voltage is within acceptable limits.
Description: Fusing Central Thermopile Does Not Reload (Low Voltage) When the fusing central thermopile does not reach a predetermined temperature for 7 seconds consecutively.
Causes: • Thermopile lens dirt • Thermopile modification/float • Outside input voltage guarantee • After excessive temperature rise prevention unit operation
Remedy: • Replace the thermopile. • Check that the input voltage is within acceptable limits.
Description: Fusing Central Thermopile Does Not Reload (Low Voltage) When the fusing central thermopile does not reach the permission temperature of heat central reloading for specified seconds continuously.
Causes: • Thermopile lens dirt • Thermopile modification/float • Outside input voltage guarantee • After excessive temperature rise prevention unit operation
Remedy: • Replace the thermopile. • Check that the input voltage is within acceptable limits.
Description: Fusing Central Thermopile High Temperature Detection (Software) When the fusing central thermopile detects a predetermined temperature or above for specified seconds consecutively. Detection period 100ms, detection count: 10 times or more.
Description: Fusing High Temperature Detection (hardware) (Central Thermopile High Temperature Error) In the event of an error
Causes: • Triac defective (short-circuit) • Engine controller defective • Heating central thermopile defective • Fusing control software: out of control
Remedy: • If the triac is defective, replace the AC power supply board. • If necessary, replace the BCU or the heating central thermopile.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.