Description: Zero cross signal error
One of the following occurred: 1) The fusing relay remained off for 50 ms after power on and continued to remain off after the after 3 attempts to detect the zero-cross signal. 2) During 11 zero-cross signal detections, two zero-cross signal detections were below 44 Hz. 3) The zero-cross signal could not be detected within 3 sec. after the fusing relay switched on.
Causes: • Switch the main switch off and on • Defective fusing relay, replace the PSU
Description: Fusing unit jam
The fusing exit sensor detected a fusing unit paper late jam three times. The paper was late and the fusing exit sensor could not detect the paper three times.
Causes: • Remove the paper that is stopped in the fusing unit. • Check that the fusing unit is clean and has no obstacles in the paper feed path. • If the error persists, replace the fusing unit
Description: Communication error between BICU and scanner unit
Within 800 ms after power on, after 3 attempts the BICU does not communicate with the SIB via the serial line.
Causes: • Serial line connecting the BICU and SIB defective • External noise on the serial line • SIB board defective • BICU board defective
Description: Communication timeout error between BICU and ADF
The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the ARDF.
Causes: • BICU board and ADF main board serial line connection defective • External noise • ADF main board defective • BICU board defective