Các lỗi thường gặp

Code :
  • Code: 547
  • Description: Zero cross signal error
    One of the following occurred: 1) The fusing relay remained off for 50 ms after power on and continued to remain off after the after 3 attempts to detect the zero-cross signal. 2) During 11 zero-cross signal detections, two zero-cross signal detections were below 44 Hz. 3) The zero-cross signal could not be detected within 3 sec. after the fusing relay switched on.
  • Causes: • Switch the main switch off and on • Defective fusing relay, replace the PSU
  • Code: 548
  • Description: Fusing unit installation error
    The machine cannot detect the fusing unit when the front cover and right cover are closed.
  • Causes: • Fusing unit is not installed • Fusing unit connection loose
  • Code: 557
  • Description: Zero-cross frequencyover
    The applied power ac frequency was detected less than 66 Hz more than 10 times, or less than 44 Hz one time.
  • Causes: • Nose on the ac power line
  • Code: 559
  • Description: Fusing unit jam
    The fusing exit sensor detected a fusing unit paper late jam three times. The paper was late and the fusing exit sensor could not detect the paper three times.
  • Causes: • Remove the paper that is stopped in the fusing unit. • Check that the fusing unit is clean and has no obstacles in the paper feed path. • If the error persists, replace the fusing unit
  • Code: 599
  • Description: 1-Bin tray motor lock
    A 1-bin tray motor lock signal is not detected for more than 300 ms during rotation.
  • Causes: • 1-bin tray motor locked from overload • 1-bin tray motor defective • 1-bin tray motor connection loose
  • Code: 601
  • Description: Communication error between BICU and scanner unit
    Within 800 ms after power on, after 3 attempts the BICU does not communicate with the SIB via the serial line.
  • Causes: • Serial line connecting the BICU and SIB defective • External noise on the serial line • SIB board defective • BICU board defective
  • Code: 610
  • Description: Communication timeout error between BICU and ADF
    The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the ARDF.
  • Causes: • BICU board and ADF main board serial line connection defective • External noise • ADF main board defective • BICU board defective
  • Code: 611
  • Description: Communication break error between BICU and ADF
    The BICU receives a break signal from the ADF main board.
  • Causes: • Serial line connecting BICU and ADF unstable • External noise • ADF main board defective • BICU board defective