Description: Potential sensor calibration error 4
During drum potential sensor calibration when adjusting the drum potential (VH) for LD power adjustment, the first time the VH pattern is made, the drum potential sensor detects that VH is more than 500V: VH > |–500 + VL + 130| V
Description: Potential sensor calibration error 5
During drum potential sensor calibration, when –100V is applied to the drum, the output value is out of the prescribed range
Causes: • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defectiv
Description: Potential sensor calibration error 6
During drum potential sensor calibration, when –800V is applied to the drum, the output value is out of the prescribed range.
Causes: • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Development power pack defective
Description: Potential sensor calibration error 7
During drum potential sensor calibration, when VL is adjusted, the pattern surface potential VL pattern is not within range 0V ~ –400V. (VL is the potential after exposing a white pattern.)
Causes: • Potential sensor defective
• Potential sensor harness disconnected
• Potential sensor connector defective or disconnected
• IOB defective
• OPC connector defective
• Charge corona power pack defective
• Development power pack defective
Description: Laser synchronization detector error
After the polygon motor reaches standard rotation speed and the LD unit fires for 500 ms, the laser synchronization detector does not generate a signal
Causes: • Harness between detector and I/F disconnected or damaged
• Detector is installed incorrectly
• Detector board is defective
• IPU board defective