Code: SC128

Description: Scanner Motor Error 4
The scanner motor speed does not reach the target speed by the time the scanning start point is reached.
Causes: • Scanner motor defective
• Overload on scanner mechanism • PSU-Eb board defective
• MCU board defective (scanner motor control unit)

Code: SC129

Description: Scanner Motor Error 5
The scanner motor speed is abnormal. The machine will not stop scanning even after the machine detects that motor speed is abnormal.
Causes: • Scanner motor defective
• Scanner drive mechanism defective
• PSU-Eb board defective
• MCU board defective (scanner motor control unit)

Code: SC141

Description: Black level detection error
When the scanner was turned on, AGC (automatic gain control) failed to achieve the target value of 10 ±3.
Causes: • SBUÅÆ IPU harnesses defective
• BCU ÅÆ IPU harnesses defective
• SBU defective
• IPU defective
• BCU defective

Code: SC142

Description: White level detection error
When the scanner was turned on, the second sampling by AGC (automatic gain control) failed to achieve a value within the range –7 to 0 of the target value 128.
Causes: • Standard white plate defective, dirty
• Moisture inside the scanner unit
• SBUÅÆ IPU harnesses defective
• BCU ÅÆ IPU harnesses defective
• SBU defective
• IPU defective
• BCU defective

Code: SC143

Description: SBU Error 1
When the scanner was turned on, the SBU (Sensor Board Unit) level adjustment, black level check, and final SBU white level check failed.
Causes: • SBU defective
• IPU defective
• BCU defective
• Harness between the SBU and IPU defective
• Harness between the BCU-IPU defective
• Standard white plate not installed correctly, or is dirty
• Scanner mirrors and/or lenses are dirty or installed incorrectly

Code: SC144

Description: SBU Error 2
At power on:
• The SYDI terminal signal did not go HIGH within 1 s
• The specified SBU (Sensor Board Unit) ID (GASBUP and LM98513) could not be read after 3 tries
Causes: • SBU defective
• BCU defective
• Harness between SBU and IPU defective

Code: SC161

Description: IPU Error
At power on, or when the machine returns from an energy save mode, the self-diagnostic program returned an IPU error.
Causes: • IPU defective
• Connection between SBU and IPU is loose, broken, or defective

Code: SC165

Description: Illegal Copy Data Security Error
The "Data Security for Copying Feature" in the User Tools is set to "ON" without the ICIB-2 installed.
Causes: • Copy Data Security Unit option board is not installed
• Copy Data Security Unit board is defective
Note:
• The "Data Security for Copying" feature in the User Tools must be set to "OFF" before the ICIB-2 is removed.
• To switch this feature off/on: [User Tools]> System Settings> Administrator Tools> Next.> Data Security for Copying> Select Off/On.