Description: GBSBU reset error
The GBSBU cannot be reset at power on or recovery from the energy save mode
Causes: • Insufficient power supply for SBU • Defective SBU • Defective harness • Defective detection port on the BCU
Code: 144-004
Description: Cannot finish the SBU communication.
The communication between BCU and SBU has not completed.
Causes: • Insufficient power supply for SBU • Defective SBU • Defective harness • Defective detection port on the BCU
Code: 161-001
Description: IPU error The error result of self-diagnostic by the Taurus (ASIC on the IPU) is detected.not completed.
Causes: • Defective IPU • Defective BCU • Defective connection between IPU and SBU
Code: 161-002
Description: ASIC (Taurus) memory error
The memory check error of ASIC (Taurus) is detected when a machine turns on or recovers from the energy saver mode.
Causes: • Defective IPU (Taurus memory) • Unusual power source
Code: 165
Description: Copy Data Security Unit error
• The copy data security board is not detected when the copy data security function is set "ON" with the initial setting. • A device check error occurs when the copy data security function is set "ON" with the initial setting.
Causes: • Incorrect installation of the copy data security board • Defective copy data security board
Code: 200
Description: Maintenance unit home position error
• The maintenance unit sensor does not get "OFF" signal after the maintenance unit motor has rotated. • The maintenance unit sensor does not get "ON" signal even the maintenance unit motor has rotated for certain time when it is assumed that the maintenance unit has to return to the home position.
Causes: • Defective maintenance unit home position sensor • Defective maintenance unit drive motor
Code: 202
Description: Tank full lever error
• The position of the tank full lever does not stay at the tank full position after ink initialization or air releasing. • The position of the tank full lever is not detected at ink suction.
Causes: • Defective tank full sensor • Tank full lever bent or broken • Incorrect ink suction
Code: 210
Description: Main scan encoder signal error
The input signal from the main scan encoder is not detected during operation of the main scan motor.
Causes: • Defective main scan encoder • Defective main scan encoder sensor • Defective main scan drive motor