Code: SC572-04

Description: Pressurized Edge Thermistor Does Not Reload After starting continuous job with paper width of 257mm or more, does not reach (T22) degrees C after (t313) seconds.
Causes: • Thermistor dirt • Thermistor deformation, float • Outside input voltage guarantee • After excess temperature rise prevention unit operation
Remedy: • Replace the thermistor • Make sure that the input voltage is within acceptable limits • Replace the fusing unit

Code: SC573-00

Description: Pressurized Edge Thermistor High Temperature Detection (software) Above (T3) degrees C detected for (t4) seconds continuously. Detection period: 100ms, detection count: 10 times or more.
Causes: • Triac short-circuit • IOB defective • BCU defective
Remedy: • Replace the IOB • Replace the BCU • Replace the fusing unit

Code: SC574-00

Description: Pressurized Edge Thermistor High Temperature Detection (hardware) Above (T4) degrees C detected
Causes: • Triac short-circuit • IOB defective • BCU defective • Fusing control: out of control
Remedy: • Replace the IOB • Replace the BCU • Replace the fusing unit

Code: SC581-00

Description: Pressurized Expanded Edge Thermistor Disconnection Below 0 degree C (or above 3F9) detected for (t12) seconds continuously. Detection period: 100ms, detection count: 10 times or more.
Causes: • Thermistor disconnection • Connector disconnected
Remedy: • Replace the thermistor • Reset the connector • Replace the connector • Replace the fusing unit

Code: SC582-04

Description: Pressurized Expanded Edge Thermistor Does Not Reload After starting continuous job with paper width of 257mm or more, does not reach (T22) degrees C after (t313) seconds.
Causes: • Thermistor dirt • Thermistor deformation, float • Outside input voltage guarantee • After excess temperature rise prevention unit operation
Remedy: • Replace the thermistor • Make sure that the input voltage is within acceptable limits • Replace the fusing unit

Code: SC583-00

Description: Pressurized Expanded Edge Thermistor High Temperature Detection (software) Above (T3) degrees C detected for (t4) seconds continuously. Detection period: 100ms, detection count: 10 times or more.
Causes: • Triac short-circuit • IOB defective • BCU defective
Remedy: • Replace the IOB • Replace the BCU • Replace the fusing unit

Code: SC584-00

Description: Pressurized Expanded Edge Thermistor High Temperature Detection (hardware) Above (T4) degrees C detected
Causes: • Triac short-circuit • IOB controller defective • BCU controller defective • Fusing control: out of control
Remedy: • Replace the IOB • Replace the BCU • Replace the fusing unit

Code: SC620-01

Description: ADF Communication error After ADF connection was recognized on startup, an error is detected. (disconnection detection)
Causes: • ADF connection fault • ADF defection • IPU board defection • Noise contamination
Remedy: • Check the ADF cable connection • Replace the ADF • Replace the IPU board
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie