Code: SC544-01

Description: Fusing central thermopile high temperature detection (hardware) In the event of an error
Causes: • Triac defective (short-circuit) • Engine controller defective • Heating central thermopile defective • Fusing control software: out of control
Remedy: • If the triac is defective, replace the AC power supply board • If necessary, replace the BCU or the heating central thermopile

Code: SC544-02

Description: Fusing central NC sensor high temperature detection (hardware) In the event of an error
Causes: • Triac defective (short-circuit) • Engine controller defective • Heating central thermopile defective • Fusing control software: out of control
Remedy: • Attach the new fusing unit, then run SP-5-810-002 • If the triac is defective, replace the AC power supply board • If necessary, replace the BCU or the Fusing central NC sensor

Code: SC545-00

Description: Fusing central heater continuously Heat After waiting for full power for more than (t6) seconds continuously, not detected for (t8) seconds. • Definition of heater full power Continuously heating rate set point (maximum heating rate) • Measurement start point After reload (after heater extinguished, after rotation complete) below the standby temperature (target temperature), measurement starts after a heater heat-up request is issued. • Measurement stop condition Rotation started due to a print signal during measurement or other. • Maximum heat-up Duty (SP interlinked value) 0% is excluded.
Causes: • Thermistor deformation/float • Heater disconnection • After excessive temperature rise prevention unit operates
Remedy: • Replace the thermistor • Replace the fusing lamp • Replace the fusing unit

Code: SC547-01

Description: Zero cross error (relay-contact soldering) In the event of an error
Causes: • Fusing relay defective (contact soldering) • Fusing relay drive circuit fault
Remedy: • Turn the main power supply switch OFF/ON • If the fusing relay is damaged, replace the PSU • Check the connection between PSU and control board, and replace harness and board if necessary

Code: SC547-02

Description: Zero cross error (relay contact fault) In the event of an error
Causes: • Fusing relay damage (contact open) • Fusing relay drive circuit fault • PSU fuse (24VS) blowout
Remedy: • Turn the main power supply switch OFF/ON • If the fusing relay is damaged, replace the PSU • Check the connection between PSU and control board, and replace harness and board if necessary • If the PSU fuse (24VS) blows out, replace the fuse

Code: SC547-03

Description: Zero cross error (low-frequency error) In the event of an error
Causes: Frequency instability of commercial power line
Remedy: • Turn the main power supply switch OFF/ON • Check the power source • Check the connection between PSU and control board, and replace harness and board if necessary

Code: SC548-00

Description: Fusing Rotation Detection During heating, there is no input to the edge of the rotation sensor (t7) ms.
Causes: • Motor defective • Sensor defective • Sensor actuator/feeler modification/defective
Remedy: • Replace the motor • Replace the sensor • Replace the actuator/feeler • Replace the fusing unit

Code: SC551-01

Description: Fusing Edge Thermopile Disconnection Below -50 degrees C (or below CB) is detected for (t11) seconds continuously.˜
Causes: • Thermopile disconnection • Connector disconnected
Remedy: • Replace the thermopile • Reset the connector • Replace the connector • Replace the fusing unit