Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Description: Toner Cartridge: ID Chip Communication Error • When abnormality occurs at cable connection • When error notification was received during communication with the tag and operation is not resumed after 3 retries.
Causes: There was an error during (wired) communication with the ID chip on the toner bottle.
Remedy: • Replace the development unit SC branch number: 01, 06, 11, 16, 21, 26, 31, 36: K 02, 07, 12, 17, 22, 27, 32, 37: M 03, 08, 13, 18, 23, 28, 33, 38: C 04, 09, 14, 19, 24, 29, 34, 39: Y
Causes: When error notification was received during communication with the tag and operation is not resumed after 3 retries. • HST sensor defective • EEPROM defective • PCU set error 01 - 04 • Device ID data corruption 06 - 09 • Connection fault (bus disconnect, etc.) 11 - 14 • No ID chip 16 – 19, 21 – 24, 26 - 29 • Noise 31 - 34, 36 - 39 • Software defection
Description: Base Plate Lift Motor Error (1-pass ADF) Even if the base plate motor is rotated in the base plate ascent direction, the base plate paper feed correct position sensor does not detect. Even if the base plate motor is rotated in the base plate descent direction, the base plate home position sensor does not detect.
Causes: • Base plate paper feed correct position sensor error (output error) • Base plate home position sensor error (output error) • Base plate motor error (does not rotate) • Controller error
Remedy: -01, 02 • Check the sensor harness and motor harness connection • Replace the sensor harness and motor harness • Replace the sensor • Replace the motor • Replace the controller -04, 05, 06, 07, 09 • Check the harness connection • Replace the harness • Replace the motor 5. Troubleshooting
Description: Original Pick-up Error (1-pass ADF) Even if the pick up arm motor is rotated, the pick up arm home position sensor does not detect.
Causes: • Pick-up home position sensor error (output error) • Pick-up motor error (does not rotate) • Controller error
Remedy: -01, 02 • Check the sensor harness and motor harness connection • Replace the sensor harness and motor harness • Replace the sensor • Replace the motor • Replace the controller -04, 05, 06, 07, 09 • Check the harness connection • Replace the harness • Replace the motor 5. Troubleshooting
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.