Description: Polygon Motor: OFF Timeout Error The XSCRDY signal (polygon ready) never becomes inactive (H) within 3 sec. after the polygon motor went OFF.
Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective • Polygon motor drive pulse cannot be output correctly. (Polygon controller) • XSCRDY signal observation failing (Polygon controller)
Remedy: • Turn the power off/on • Replace the LSU or polygon motor • Replace the polygon harness • Replace the IPU board
Description: Polygon Motor: XSCRDY Signal Error During polygon motor rotation, the XSCRDY signal was inactive (H) for longer than one rotation of the polygon.
Causes: • The interface harness to the polygon motor driver damaged or not connected correctly. • Polygon motor or polygon motor driver defective
Remedy: • Turn the power off/on • Replace the LSU or polygon motor • Replace the polygon harness • Replace the IPU board
Description: Leading Edge: LD1 synchronization detection error: Bk The leading edge LD0 synchronization detection signal of the corresponding color was not output within T1 sec. while the polygon mirror motor was operating at normal speed.
Causes: • The interface harness to the synchronization detection unit damaged or not connected correctly. • Synchronization detection board defective • Beam does not enter photo detector. • Abnormality around GAVD • IDB (LED driver) defective • LDB defective • BCU defective
Remedy: • Turn the power off/on • Replace the LSU or polygon motor • Replace the polygon harness • Replace the IPU board
Description: Leading Edge: LD1 synchronization detection error: Ye The leading edge LD0 synchronization detection signal of the corresponding color was not output within T1 sec. while the polygon mirror motor was operating at normal speed.
Causes: • The interface harness to the synchronization detection unit damaged or not connected correctly. • Synchronization detection board defective • Beam does not enter photo detector. • Abnormality around GAVD • IDB (LED driver) defective • LDB defective • BCU defective
Remedy: • Turn the power off/on • Replace the LSU or polygon motor • Replace the polygon harness • Replace the IPU board