Description: Incorrect dial up connection -001: Program parameter error -002: Program execution error An unexpected error occurs when the modem (Cumin-M) tries to call the center with a dial up connection.
Causes: Caused by a software bug
Remedy: No action required because this SC does not interfere with operation of the machine.
Code: 669
Description: EEPROM error Retry of EEPROM communication fails three times after the machine has detected the EEPROM error.
Causes: Caused by noise
Remedy: Turn the main power switch off and on.
Code: 670
Description: No response from BICU at power on When the main power is turned on or the machine starts warming up from energy-saving mode, the controller does not receive a command signal from the BICU.
Remedy: 1. Check the connection between the BICU and controller. 2. Replace the controller. 3. Replace the BICU.
Code: 672
Description: Controller-to-operation panel communication error at startup After the machine is powered on, the communication between the controller and the operation panel is not established, or communication with controller is interrupted after a normal startup. After startup reset of the operation panel, the attention code or the attention acknowledge code is not sent from the controller within 15 seconds. After the controller issues a command to check the communication line with the controller at 30-second intervals, the controller fails to respond twice.
Causes: Controller stalled. Controller board installed incorrectly. Controller board defective. Operation panel connector loose or defective. The controller is not completely shutdown when you turn the main switch off.
Remedy: 1. Check the setting of SP5875-001. If the setting is set to "1 (OFF)", change it to "0 (OFF)". 2. Check the condition of the controller board. 3. Check the condition of the operation panel. 4. Replace the controller board. 5. Replace the operation panel. 6. Turn the main switch off, wait for one second or more, and turn the main switch on.
Code: 681
Description: RFID: Communication error Communication error occurs when the RFID starts to communicate with the RFID receptor. Retry of RFID communication fails three times after the machine has detected the RFID communication error.
Causes: Defective RFID reader and writer. Disconnected ASAP I/F. No memory chip on the toner cartridge. Noise.
Remedy: 1. Replace the RFID controller board. 2. Replace the toner cartridge.
Code: 682
Description: Memory chip at TD sensor: Communication error Retry of memory chip communication fails three times after the machine has detected the memory chip communication error.
Causes: Damaged memory chip data. Disconnected inter face. No memory chip on the development unit. Noise.
Remedy: 1. Replace the PCU.
Code: 683
Description: RFID: Unit check error The machine gets RFID communication error even the toner cartridges have not been installed in the machine.
Causes: Caused by noise
Remedy: 1. Turn the main power switch off and on.
Code: 687
Description: Memory address command error The BICU does not receive a memory address command from the controller 120 seconds after paper is in the position for registration.