Description: Heating roller fusing lamp consecutive full power 1 When the fusing unit is not running in the ready condition, the heating roller fusing lamp keeps on full power for 8 seconds.
Causes: Broken heating roller thermistor
Remedy:
Code: 547
Description: Zero cross error The zero cross signal is detected three times even though the heater relay is off when turning on the main power. The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door. The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Remedy: 1. Check that the pressure roller thermistor is firmly connected. 2. Replace the thermopile.
Code: 552
Description: Pressure roller warm-up error After the main switch is turned on or the door is closed, the pressure roller temperature does not reach the ready temperature within 70 seconds during fusing unit warm-up.
Causes: Pressure roller fusing lamp broken
Remedy: 1. Check if the pressure roller thermistor is firmly connected. 2. Replace the pressure roller fusing lamp.
Code: 553
Description: Pressure roller fusing lamp overheat (software error) The detected pressure roller temperature stays at 230°C or more for 1 second.
Remedy: 1. Replace the pressure roller thermistor. 2. Replace the PSU. 3. Replace the IOB. 4. Replace the BICU.
Code: 555
Description: Pressure roller lamp consecutive full power 2 When the fusing unit is not running in the ready condition, the pressure roller-fusing lamp keeps ON full power for 8 seconds or more.
Causes: Broken pressure roller fusing lamp
Remedy: 1. Replace the pressure roller fusing lamp. 2. Replace the PSU.
Code: 557
Description: Zero cross frequency error When the zero cross signal is 66 or more and it is detected 10 times or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs.