Description: MUSIC error The results of MUSIC pattern reading failed 4 times. (even if mode e (real time MUSIC) fails, the error count is not incremented (+1))
Causes: • TM sensor defective • ITB defective • PCU defective • LD unit defective • MUSIC pattern density thin
Remedy: • ITB reset • PCU reset • Toner replenishment • Replace the TM (ID) sensor • Replace the ITB • Replace the PCU • Replace the LD unit
Description: Charge Roller HVP_CB Output Error (K) Charging AC is set to ON at the standard speed, and the FB voltage of the charging AC of each color is monitored for 200 ms at 20ms intervals (10 times) after 80ms of charge AC_ON, and below 0.3V is detected continuously for 200ms (10 times), the SC of the corresponding color lights up, and machine operation is suspended.
Causes: • High voltage harness defective or shorted. • PCU setting fault or damage • HVP_CB fault • Connector disconnected • Harness broken
Remedy: • High voltage harness reset/replacement • PCU reset/replacement • Replace the HVP_CB • Connector reset • Replace the harness
Description: Charge Roller HVP_CB Output Error (C) Charging AC is set to ON at the standard speed, and the FB voltage of the charging AC of each color is monitored for 200 ms at 20ms intervals (10 times) after 80ms of charge AC_ON, and below 0.3V is detected continuously for 200ms (10 times), the SC of the corresponding color lights up, and machine operation is suspended.
Causes: • High voltage harness defective or shorted. • PCU setting fault or damage • HVP_CB fault • Connector disconnected • Harness broken
Remedy: • High voltage harness reset/replacement • PCU reset/replacement • Replace the HVP_CB • Connector reset • Replace the harness
Description: Charge Roller HVP_CB Output Error (M) Charging AC is set to ON at the standard speed, and the FB voltage of the charging AC of each color is monitored for 200 ms at 20ms intervals (10 times) after 80ms of charge AC_ON, and below 0.3V is detected continuously for 200ms (10 times), the SC of the corresponding color lights up, and machine operation is suspended.
Causes: • High voltage harness defective or shorted. • PCU setting fault or damage • HVP_CB fault • Connector disconnected • Harness broken
Remedy: • High voltage harness reset/replacement • PCU reset/replacement • Replace the HVP_CB • Connector reset • Replace the harness
Description: Charge Roller HVP_CB Output Error (Y) Charging AC is set to ON at the standard speed, and the FB voltage of the charging AC of each color is monitored for 200 ms at 20ms intervals (10 times) after 80ms of charge AC_ON, and below 0.3V is detected continuously for 200ms (10 times), the SC of the corresponding color lights up, and machine operation is suspended.
Causes: • High voltage harness defective or shorted. • PCU setting fault or damage • HVP_CB fault • Connector disconnected • Harness broken
Remedy: • High voltage harness reset/replacement • PCU reset/replacement • Replace the HVP_CB • Connector reset • Replace the harness
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.