Description: 3rd paper tray lift motor malfunction (optional paper feed unit) The paper lift sensor does not detect paper or finish the detection within the specified time, after the tray lift motor switched on.
Causes: An obstruction (jammed paper, paper scraps, etc.) has blocked the motor drive and caused an overload. Paper lift sensor connection loose, disconnected, or damaged Paper lift sensor defective Tray lift motor connection loose, disconnected, or damaged Tray lift motor defective
Remedy: 1. Check or replace the connector and harness. 2. Replace the tray lift motor.
Description: By-pass bottom plate error The signal from the by-pass tray HP sensor does not change for 2 seconds after the by-pass bottom plate clutch was activated. If this condition occurs three consecutive times, this SC is generated.
Causes: Disconnected or defective connectors of the by-pass bottom plate clutch. Disconnected or defective by-pass HP sensor. Defective by-pass bottom plate detection filler
Remedy: 1. Check or replace the connectors of the by-pass bottom plate clutch. 2. Check or replace the by-pass HP sensor.
Description: Transport motor error The machine detects a High signal from a transport motor lock detection for 2 seconds after the transport motor turned on.
Causes: Unit overload. Defective motor.
Remedy: 1. Replace the unit. 2. Replace the motor.
Description: Fusing heater exhaust fan motor error The motor lock signal error is detected 50 consecutive times (5 seconds) after the motor lock signal was first detected.
Causes: Defective fan motor. Disconnected or defective harness. Defective BICU
Remedy: 1. Check or replace the harness. 2. Replace the fan motor. 3. Replace the BICU.
Description: Development cooling fan motor error The motor lock signal error is detected 50 consecutive times (5 seconds) after the motor lock signal was first detected.
Causes: Defective fan motor. Disconnected or defective harness. Defective BICU
Remedy: 1. Check or replace the harness. 2. Replace the fan motor. 3. Replace the BICU.
Description: Writing cooling fan motor error The motor lock signal error is detected 50 consecutive times (5 seconds) after the motor lock signal was first detected.
Causes: Defective fan motor. Disconnected or defective harness. Defective BICU
Remedy: 1. Check or replace the harness. 2. Replace the fan motor. 3. Replace the BICU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.