Description: TD sensor (Vt) upper limit error: Bk The Vt value upper limit of the black TD sensor (SP3210-001) exceeds the specified value (SP3211-002) for the specified number of times (SP3211-003) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Description: TD sensor (Vt) upper limit error 1: Cy The Vt value upper limit of the cyan TD sensor (SP3210-002) exceeds the specified value (SP3211-002) for the specified number of times (SP3211-003) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Description: TD sensor (Vt) upper limit error 1: Ma The Vt value upper limit of the magenta TD sensor (SP3210-003) exceeds the specified value (SP3211-002) for the specified number of times (SP3211-003) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Description: TD sensor (Vt) upper limit error 1: Ye The Vt value upper limit of the yellow TD sensor (SP3210-004) exceeds the specified value (SP3211-002) for the specified number of times (SP3211-003) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Description: TD sensor (Vt) lower limit error: Bk The Vt value lower limit of the black TD sensor (SP3210-001) falls below the specified value (SP3211-004) for the specified number of times (SP3211-005) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Description: TD sensor (Vt) lower limit error 1: Cy The Vt value lower limit of the cyan TD sensor (SP3210-002) falls below the specified value (SP3211-004) for the specified number of times (SP3211-005) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Description: TD sensor (Vt) lower limit error 1: Ma The Vt value lower limit of the magenta TD sensor (SP3210-003) falls below the specified value (SP3211-004) for the specified number of times (SP3211-005) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Description: TD sensor (Vt) lower limit error 1: Ye The Vt value lower limit of the yellow TD sensor (SP3210-004) falls below the specified value (SP3211-004) for the specified number of times (SP3211-005) consecutively.
Causes: Black, cyan, magenta, or yellow TD sensor disconnected. Harness between TD sensor and PCDU defective. Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU. 2. Check the drawer connector. 3. Replace the defective TD sensor.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.