Description: Engine is down when machine starts up (SC reboot can not be performed) (* See “When SC670 Is Displayed” below). Machine-down was detected after the /ENGRDY signal was not asserted.
Causes: The engine board was reset at an unexpected time
Remedy: Check the connection between the engine board and the controller board. • If it is always reproduced, replace the engine board. If the problem persists, consider replacing the controller board or other boards between them. • If reproducibility is low, multiple causes are to be considered, such as software, engine board, controller board, and PSU.
Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established.
Remedy: • Cycle the main power off and on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established.
Remedy: • Cycle the main power off and on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup.
Remedy: • Cycle the main power off and on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness. • Make sure that only DIP switch number 3 is ON.
Remedy: • Cycle the main power off and on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Description: Controller start up error The operation panel detects that the controller is down due to other reason shown in SC672-10, SC672-11, and SC672-12.
Remedy: • Cycle the main power off and on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Description: Operation panel Flair communication error (Smart Operation Panel) This SC is issued only for the machine that has the Smart Operation Panel installed. • Communication between Smart Operation Panel and main machine (this is called “Flair communication”) is not sent to Smart Operation Panel. • SP setting (SP5-748-201) for Smart Operation Panel is not activated.
Causes: The CATS module (controller) did not see the response to notification of monitoring service module (operation panel)
Remedy: • Cycle the main power off and on. • Set SP5-748-201 to “1: Connect” if the value is “0: Not connect”
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.