Remedy: 1. Turn the main switch off and on. 2. Reinstall the controller and/or engine main firmware.
Code: 991
Description: Software continuity error The software has attempted to perform an unexpected operation. However, unlike SC 990, the object of the error is continuity of the software.
Causes: • Software program error • Internal parameter incorrect, insufficient working memory.
Remedy: 1. This SC is not displayed on the LCD (logging only).
Code: 992
Description: Undefined error Defective software program
Causes: • An error undetectable by any other SC code occurred
Remedy:
Code: 994
Description: Operation panel management records exceeded An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware. This can occur if there if there are too many application screens open on the operation panel.
Causes: • No action required because this SC does not interfere with operation of the machine.
Remedy:
Code: 995
Description: Controller Board Mismatch The information on the controller board does not match that of the machine
Causes: • Wrong controller board installed
Remedy: Reinstall the correct controller board for this machine.
Code: 997
Description: Application function selection error • The application selected by the operation panel key does not start or ends abnormally.
Causes: • Software (including the software configuration) defective • An option required by the application (RAM, DIMM, board) is not installed • Nesting of the fax group addresses is too complicated
Remedy: 1. Check the devices necessary for the application program. If necessary devices have not been installed, install them. 2. Check that application programs are correctly configured. 3. For a fax operation problem, simplify the nesting of the fax group addresses. 4. Take necessary countermeasures specific to the application program. If the logs can be displayed on the operation panel, see the logs.
Code: 998
Description: Application start error No applications start within 60 seconds after the power is turned on.
Causes: • Loose connection of RAM-DIMM, ROM-DIMM • Defective controller • Software problem