Description: IPU error The error result of self-diagnostic by the Taurus (ASIC on the IPU) is detected.
Causes: • Defective IPU • Defective connection between IPU and SBU
Remedy: 1. Check the connection between IPU and SBU. 2. Replace the IPU.
Code: 165
Description: Copy Data Security Unit error • The copy data security board is not detected when the copy data security function is set "ON" with the initial setting. • A device check error occurs when the copy data security function is set "ON" with the initial setting.
Causes: • Incorrect installation of the copy data security board • Defective copy data security board
Remedy: 1. Reinstall the copy data security board. 2. Replace the copy data security board.
Code: 195
Description: Serial Number Mismatch • Serial number stored in the memory does not have the correct code.
Causes: • NVRAM defective • BCU replaced without original NVRAM
Remedy: 1. Check the serial number with SP5-811-002. 2. If the stored serial number is incorrect, contact your supervisor.
Code: 202
Description: Polygon motor error 1: ON timeout The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
Causes: • Defective or disconnected harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor.
Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the IPU.
Code: 203
Description: Polygon motor error 2: OFF timeout The polygon mirror motor does leave the READY status within 3 seconds after the polygon motor switches off.
Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor
Remedy: 1. Check or replace the harness. 2. Replace the polygon motor.
Code: 204
Description: Polygon motor error 3: XSCRDY signal error The SCRDY_N signal goes HIGH (inactive) while the laser diode is firing.
Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor • Defective polygon motor driver board
Remedy: 1. Check or replace the harness. 2. Replace the polygon motor.
Code: 210
Description: Laser synchronizing detection error: end position [K] The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: • Disconnected or defective harness to synchronizing detector for end position • Defective synchronizing detector board • Defective LD board or driver • Defective IPU
Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the IPU.
Code: 211
Description: Laser synchronizing detection error: end position [Y] The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: • Disconnected or defective harness to synchronizing detector for end position • Defective synchronizing detector board • Defective LD board or driver • Defective IPU
Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the IPU.