Mã lỗi Ricoh Aficio MPC3501 — Trang 16/25

Code: 651

Description: Incorrect dial up connection
-001: Program parameter error -002: Program execution error An unexpected error occurs when the modem (Cumin-M) tries to call the center with a dial up connection.
Causes: • Caused by a software bug
Remedy: No action required because this SC does not interfere with operation of the machine.

Code: 669

Description: EEPROM error
Retry of EEPROM communication fails three times after the machine has detected the EEPROM error.
Causes: • Caused by noise
Remedy: Turn the main power switch off and on.

Code: 670

Description: Engine start up error
The ready signal from the engine board is not detected.
Causes: • Defective engine board.
Remedy: Replace the BICU.

Code: 671

Description: Engine board mismatch error
Engine board and controller mismatch detected.
Causes: • Wrong engine board installed. • Wrong controller board installed. • Check the type of engine board and controller board.
Remedy: 1. Replace the BICU. 2. Replace the controller board.

Code: 672

Description: Controller-to-operation panel communication error at startup
After powering on the machine, the communication circuit between the controller and the operation panel is not opened, or communication with controller is interrupted after a normal startup.
Causes: • Controller stall • Controller board installed incorrectly • Controller board defective • Operation panel connector loose or defective
Remedy: 1. Check the harness connection. 2. Replace the controller board.

Code: 681

Description: RFID: Communication error
• Communication error occurs when the RFID starts to communicate with the RFID receptor. • Retry of RFID communication fails three times after the machine has detected the RFID communication error.
Causes: • Defective RFID reader and writer • Disconnected ASAP I/F • No memory chip on the toner cartridge • Noise
Remedy: 1. Replace the RFID controller board. 2. Replace the toner cartridge.

Code: 682

Description: Memory chip at TD sensor: Communication error
Retry of memory chip communication fails three times after the machine has detected the memory chip communication error.
Causes: • Damaged memory chip data • Disconnected inter face • No memory chip on the development unit • Noise
Remedy: 1. Replace the PCDU. 2. Replace the BICU.

Code: 683

Description: RFID: Unit check error
The machine gets RFID communication error even the toner cartridges have not been installed in the machine.
Causes: Caused by noise
Remedy: Turn the main power switch off and on.