Description: Electric counter error Abnormal data in the counters.
Causes: • Defective NVRAM • Defective controller
Remedy: 1. Check the connection between the NVRAM and controller. 2. Replace the NVRAM. 3. Replace the controller.
Code: 910...915
Description: External Controller Error
Causes: The external controller alerted the machine about an error.
Remedy: • Please refer to the instructions for the external controller (application).
Code: 919
Description: External Controller Error 6 While EAC (External Application Converter), the conversion module, was operating normally, the receipt of a power line interrupt signal from the FLUTE serial driver was detected, or BREAK signal from the other station was detected.
Causes: • Power outage at the EFI controller • EFI controller was rebooted • Connection to EFI controller loose
Remedy:
Code: 920
Description: Printer application error An error is detected in the printer application program.
Remedy: 1. Turn the main switch off and on. 2. Reinstall the controller and/or engine main firmware. • See Note 1 at the end of the SC table.
Code: 991
Description: Software continuity error The software has attempted to perform an unexpected operation. However, unlike SC 990, the object of the error is continuity of the software.
Causes: • Software program error • Internal parameter incorrect, insufficient working memory.
Remedy: This SC is not displayed on the LCD (logging only).
Code: 992
Description: Undefined error Defective software program
Causes: • An error undetectable by any other SC code occurred
Remedy: • An error undetectable by any other SC code occurred