Code: 543

Description: Heating roller fusing lamp overheat 1 (software error)
The detected fusing temperature stays at 230°C for 1 second.
Causes: • Defective PSU • Defective IOB • Defective BICU
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.

Code: 544

Description: Heating roller fusing lamp overheat 1 (hardware error)
During stand-by mode or a print job, the detected heating roller temperature reaches 250 °C.
Causes: • Defective PSU • Defective IOB • Defective BICU • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.

Code: 547

Description: Zero cross error
• The zero cross signal is detected three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Causes: • Defective fusing lamp relay • Defective fusing lamp relay circuit • Unstable power supply
Remedy: 1. Check the power supply source. 2. Replace the +24V fuse on the PSU. 3. Replace the PSU

Code: 548

Description: Fusing unit rotation error
The heating roller rotation sensor does not detect change in the actuator for 0.5 seconds after the fusing/paper exit motor has turned on.
Causes: • Defective fusing/paper exit motor • Deformed actuator for the heating roller rotation sensor • Defective heating roller rotation sensor • Broken connection between IH inverter and IOB • Incorrectly set fusing unit
Remedy: 1. Check if the fusing unit is correctly set. 2. Check or replace the actuator for heating roller rotation sensor. 3. Replace the heating roller rotation sensor. 4. Replace the IH inverter. 5. Check the connection between IH inverter and IOB.

Code: 551

Description: Heating roller thermistor error
The temperature at the end of the heating roller measured by the heating roller thermistor does not reach 0°C for 7 seconds.
Causes: • Loose connection of pressure roller thermistor • Defective heating roller thermistor
Remedy: 1. Check that the heating roller thermistor is firmly connected. 2. Replace the heating roller thermistor.

Code: 552

Description: Heating roller warm-up error 2
• The heating roller temperature does not reach 80°C for 20 seconds after the IH inverter turned on. • The temperature at the end of the heating roller does not reach the ready temperature for 89 seconds after the IH inverter turned on.
Causes: • Defective heating roller thermistor • Defective IH inverter
Remedy: 1. Check if the heating roller thermistor is firmly connected. 2. Replace the IH inverter.

Code: 553

Description: Heating roller overheat (software error)
The detected heating roller temperature stays at 245°C or more for 1 second.
Causes: • Defective PSU • Defective IOB • Defective BICU
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.

Code: 554

Description: Heating roller overheat (hardware error)
The heating roller thermistor detects 250°C or more.
Causes: • Defective PSU • Defective IOB • Defective BICU • Defective fusing control system
Remedy: 1. Replace the PSU. 2. Replace the IOB. 3. Replace the BICU.