Code: 571-00

Description: Pressure roller thermistor error: Center
The center temperature of the pressure roller measured by the thermistor does not reach 0°C for 37 seconds.
Causes: • Loose connection of the thermistor • Defective thermistor
Remedy: 1. Check if the thermistor is firmly connected. 2. Replace the center thermistor.

Code: 572-02

Description: Pressure roller thermistor warm-up error: Center
The center temperature of the pressure roller measured by the thermistor does not reach 20°C within 100 seconds after the heater turns on.
Causes: • Dirty thermopile lenses • Defective thermistor
Remedy: 1. Clean the thermopile lenses. 2. Replace the thermistor at the end of the pressure roller.

Code: 573

Description: Pressure roller overheat : Center (software error)
The detected pressure roller temperature stays at 215°C or more for 1 second for 10 consecutive times.
Causes: • Defective IOB • Defective IPU
Remedy: 1. Replace the IOB. 2. Replace the IPU.

Code: 574

Description: Pressure roller overheat : Center (hardware error)
The thermistor detects 220°C or more.
Causes: • Defective IOB • Defective IPU • Defective fusing control system
Remedy: 1. Replace the IOB. 2. Replace the IPU.

Code: 581

Description: NC sensor broken: Center
The sensor detects -17°C or less for 100 seconds.
Causes: • Broken cables of thermopile or thermistor • Defective connection of connectors
Remedy: 1. Check and replace the connection of the cables and connectors.

Code: 591

Description: NC sensor broken: End
The sensor detects -17°C or less for 100 seconds.
Causes: • Broken cables of thermopile or thermistor • Defective connection of connectors
Remedy: 1. Check and replace the connection of the cables and connectors.

Code: 610

Description: Mechanical counter error: K
This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".
Causes: • Disconnected mechanical counter • Defective mechanical counter
Remedy: 1. Check or replace the mechanical counter.

Code: 620

Description: ARDF communication error
After the ARDF is detected, the break signal occurs or communication timeout occurs.
Causes: • Incorrect installation of ARDF • ARDF defective • BICU board defective • External noise
Remedy: 1. Check the cable connection of the ARDF. 2. Shut out the external noise. 3. Replace the ARDF. 4. Replace the IPU board.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie