Remedy: 1. Replace the thermistors. 2. Check and replace the cables.
Code: 547
Description: Zero cross error • The zero cross signal is detected three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 3 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is 39 or less.
Causes: • Defective fusing relay • Defective fusing relay circuit • Shorted +24V fuse on the AC controller board. • Unstable power supply
Remedy: 1. Check the power supply source. 2. Replace the +24V fuse on the AC controller board. 3. Replace the PSU
Code: 549
Description: Fusing heater connection error The heating roller rotation sensor detects the target temperature as 50°C for 5 seconds or more after the fusing/paper exit motor has turned on.
Remedy: 1. Check the cable connection. 2. Replace the heater cables.
Code: 551
Description: Heating roller thermistor error The temperature at the end of the heating roller measured by the heating roller thermistor does not reach 0°C for 7 seconds.
Remedy: 1. Check that the heating roller thermistor is firmly connected. 2. Replace the heating roller thermistor.
Code: 552
Description: Heating roller warm-up error 2 • The heating roller temperature does not reach 80°C for 20 seconds after the inverter turned on. • The temperature at the end of the heating roller does not reach the ready temperature for 89 seconds after the fusing lamp turned on.
Remedy: 1. Check if the heating roller thermistor is firmly connected. 2. Replace the inverter.
Code: 553
Description: Heating roller overheat: End (software error) The detected heating roller temperature stays at 215°C or more for 1 second for 10 consecutive times.