Description: QSU fan error The machine does not detect the fan motor lock signal for 100 ms while the QSU fan turns on.
Causes: • Disconnected harness • Overload on the QSU fan motor • Defective QSU fan motor • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the QSU fan. 3. Replace the IOB.
Code: 532-01
Description: Ventilation fan (at the left side of the machine) motor error: front end The IOB does not receive the lock signal for 100 ms after turning on the ventilation fan motor in the front end, rear end, front in the middle, or rear in the middle.
Causes: • Defective ventilation fan motor in the front end, rear end, front in the middle, or rear in the middle • Defective IOB
Remedy: 1. Replace the ventilation fan (at the left side of the machine) motor in the front end, rear end, front in the middle, or rear in the middle. 2. Replace the IOB.
Code: 532-02
Description: Ventilation fan (at the left side of the machine) motor error: rear end The IOB does not receive the lock signal for 100 ms after turning on the ventilation fan motor in the front end, rear end, front in the middle, or rear in the middle.
Causes: • Defective ventilation fan motor in the front end, rear end, front in the middle, or rear in the middle • Defective IOB
Remedy: 1. Replace the ventilation fan (at the left side of the machine) motor in the front end, rear end, front in the middle, or rear in the middle. 2. Replace the IOB.
Code: 532-03
Description: Ventilation fan (at the left side of the machine) motor error: front in the middle The IOB does not receive the lock signal for 100 ms after turning on the ventilation fan motor in the front end, rear end, front in the middle, or rear in the middle.
Causes: • Defective ventilation fan motor in the front end, rear end, front in the middle, or rear in the middle • Defective IOB
Remedy: 1. Replace the ventilation fan (at the left side of the machine) motor in the front end, rear end, front in the middle, or rear in the middle. 2. Replace the IOB.
Code: 532-04
Description: Ventilation fan (at the left side of the machine) motor error: rear in the middle The IOB does not receive the lock signal for 100 ms after turning on the ventilation fan motor in the front end, rear end, front in the middle, or rear in the middle.
Causes: • Defective ventilation fan motor in the front end, rear end, front in the middle, or rear in the middle • Defective IOB
Remedy: 1. Replace the ventilation fan (at the left side of the machine) motor in the front end, rear end, front in the middle, or rear in the middle. 2. Replace the IOB.
Code: 533-01
Description: Second duct fan error 1 The machine does not detect the fan motor lock signal for 100 ms while the second duct fan turns on.
Causes: • Disconnected harness • Overload on the second duct fan motor • Defective second duct motor • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the second duct fan. 3. Replace the IOB.
Code: 533-02
Description: Second duct fan error 2 The machine does not detect the fan motor lock signal for 100 ms while the second duct fan turns on.
Causes: • Disconnected harness • Overload on the second duct fan motor • Defective second duct motor • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the second duct fan. 3. Replace the IOB.
Code: 534-01
Description: Third duct fan error The machine does not detect the fan motor lock signal for 100 ms while the third duct fan or tube cooling fan turns on.
Causes: • Disconnected harness • Overload on the third duct fan motor or tube cooling fan motor • Defective third duct motor or tube cooling motor • Defective IOB
Remedy: 1. Check or replace the harness. 2. Replace the third duct fan or tube cooling fan. 3. Replace the IOB.