Description: FGATE ON error: C The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [K], [C], [M], [Y].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and IPU • Defective IPU
Remedy: 1. Check the connection between the controller board and the IPU. 2. Replace the IPU. 3. Replace the controller board.
Code: 230-03
Description: FGATE ON error: M The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [K], [C], [M], [Y].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and IPU • Defective IPU
Remedy: 1. Check the connection between the controller board and the IPU. 2. Replace the IPU. 3. Replace the controller board.
Code: 230-04
Description: FGATE ON error: Y The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for start position [K], [C], [M], [Y].
Causes: • Defective ASIC (Lupus) • Poor connection between controller and IPU • Defective IPU
Remedy: 1. Check the connection between the controller board and the IPU. 2. Replace the IPU. 3. Replace the controller board.
Code: 231-01
Description: FGATE OFF error: K • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K], [C], [M], [Y]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and IPU • Defective IPU
Remedy: 1. Check the connection between the controller board and the IPU. 2. Replace the IPU. 3. Replace the controller board.
Code: 231-02
Description: FGATE OFF error: C • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K], [C], [M], [Y]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and IPU • Defective IPU
Remedy: 1. Check the connection between the controller board and the IPU. 2. Replace the IPU. 3. Replace the controller board.
Code: 231-03
Description: FGATE OFF error: M • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K], [C], [M], [Y]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and IPU • Defective IPU
Remedy: 1. Check the connection between the controller board and the IPU. 2. Replace the IPU. 3. Replace the controller board.
Code: 231-04
Description: FGATE OFF error: Y • The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for end position [K], [C], [M], [Y]. • The PFGATE ON signal still asserts when the next job starts.
Causes: • Defective ASIC (Lupus) • Poor connection between controller and IPU • Defective IPU
Remedy: 1. Check the connection between the controller board and the IPU. 2. Replace the IPU. 3. Replace the controller board.
Code: 240-01
Description: LD error: K The IPU detects LDB error a few times consecutively when LDB unit turns on after LDB initialization.
Causes: • Worn-out LD • Disconnected or broken harness of the LD
Remedy: 1. Replace the harness of the LD. 2. Replace the laser optics housing unit. 3. Replace the IPU.