Description: Charge P.P. output error [Y] The feedback voltage of the charge AC for each color is 0.3 V or less for 0.2 seconds after the charge AC has turned on.
Causes: • Disconnected or broken harnesses of the HVPS • Defective PCDU • Defective HVPS
Remedy: 1. Check or replace the harnesses of the HVPS. 2. Reinstall or replace the PCDU. 3. Replace the HVPS.
Code: 360-01
Description: TD sensor adjustment error: K During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V) ± 0.2V
Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the defective PCDU.
Code: 360-02
Description: TD sensor adjustment error: C During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V) ± 0.2V
Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the defective PCDU.
Code: 360-03
Description: TD sensor adjustment error: M During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V) ± 0.2V
Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the defective PCDU.
Code: 360-04
Description: TD sensor adjustment error: Y During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V) ± 0.2V
Causes: • Heat seal not removed from a new developer pack • TD harness sensor disconnected, loose or defective • TD sensor defective • Harness between TD sensor and drawer disconnected, defective
Remedy: 1. Remove the heat seal from each PCDU. 2. Replace the defective PCDU.
Code: 361-01
Description: TD sensor (Vt high) error 1: K • The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3-020-002 for twenty counts. • The [Vt - Vtref] value of the black, cyan, magenta, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3-020-001.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCDU defective • Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU for damage. 2. Check the drawer connector. 3. Replace the defective PCDU.
Code: 361-02
Description: TD sensor (Vt high) error 1: C • The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3-020-002 for twenty counts. • The [Vt - Vtref] value of the black, cyan, magenta, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3-020-001.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCDU defective • Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU for damage. 2. Check the drawer connector. 3. Replace the defective PCDU.
Code: 361-03
Description: TD sensor (Vt high) error 1: M • The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3-020-002 for twenty counts. • The [Vt - Vtref] value of the black, cyan, magenta, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3-020-001.
Causes: • Black, magenta, cyan, or yellow TD sensor disconnected • Harness between TD sensor and PCDU defective • Defective TD sensor
Remedy: 1. Check the black, cyan, magenta, or yellow TD sensor connector and harness between the TD sensor and PCDU for damage. 2. Check the drawer connector. 3. Replace the defective PCDU.