Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio MPC5502 — Trang 14/30

Code: 545

Description: Fusing Heater error: Center
The fusing heater keeps full power for 23 seconds or more.
Causes: • Defective thermistors • Disconnected cables
Remedy: 1. Replace the thermistors. 2. Check and replace the cables.

Code: 547

Description: Zero cross error
• The zero cross signal is detected three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 3 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is 39 or less.
Causes: • Defective fusing relay • Defective fusing relay circuit • Shorted +24V fuse on the AC controller board. • Unstable power supply
Remedy: 1. Check the power supply source. 2. Replace the +24V fuse on the AC controller board. 3. Replace the PSU

Code: 549

Description: Fusing heater connection error
The heating roller rotation sensor detects the target temperature as 50°C for 5 seconds or more after the fusing/paper exit motor has turned on.
Causes: • Broken heater cables • Defective connectors
Remedy: 1. Check the cable connection. 2. Replace the heater cables.

Code: 551

Description: Heating roller thermistor error
The temperature at the end of the heating roller measured by the heating roller thermistor does not reach 0°C for 7 seconds.
Causes: • Loose connection of pressure roller thermistor • Defective heating roller thermistor
Remedy: 1. Check that the heating roller thermistor is firmly connected. 2. Replace the heating roller thermistor.

Code: 552

Description: Heating roller warm-up error 2
• The heating roller temperature does not reach 80°C for 20 seconds after the inverter turned on. • The temperature at the end of the heating roller does not reach the ready temperature for 89 seconds after the fusing lamp turned on.
Causes: • Defective heating roller thermistor • Defective inverter
Remedy: 1. Check if the heating roller thermistor is firmly connected. 2. Replace the inverter.

Code: 553

Description: Heating roller overheat: End (software error)
The detected heating roller temperature stays at 215°C or more for 1 second for 10 consecutive times.
Causes: • Defective AC controller board • Defective IOB • Defective IPU
Remedy: 1. Replace the AC controller board. 2. Replace the IOB. 3. Replace the IPU.

Code: 554

Description: Heating roller overheat: End (hardware error)
The heating roller thermistor detects 220°C or more.
Causes: • Defective AC controller board • Defective IOB • Defective IPU • Defective fusing control systemd
Remedy: 1. Replace the AC controller board. 2. Replace the IOB. 3. Replace the IPU.

Code: 555

Description: Fusing Heater error: End
The fusing heater keeps full power for 19 seconds or more.
Causes: • Defective thermistors • Disconnected cables
Remedy: 1. Replace the thermistors. 2. Check and replace the cables.